Section 50 - Climate Control - Chapter 1 50-1-16 Automatic Operation Summary (ATC switch set to “Auto,” and “Auto” displays on the Instrument Cluster Display. No fault codes active.) Temperature Argument Controller needs a 2°F (1°C) difference between the setpoint and temperature sensed at cab sensor before responding - engaging the compressor or opening the heater valve. Selecting a setpoint one degree cooler or warmer than the temperature desired may increase operator comfort. Blower Speed If difference between cab temperature and the setpoint is ... Then the blower speed used by the controller is ...
less than or equal to 2°F (1°C) 25% greater than 2°F (1°C) but less than or equal to 4°F (2°C) 35%* greater than 4°F (2°C) but less than or equal to 6°F (3°C) 45%* greater than 6°F (3°C) but less than or equal to 8°F (4°C) 55%* greater than 8°F (4°C) but less than or equal to 10°F (5°C) 65%* greater than 10°F (5°C) but less than or equal to 12°F (6°C) 75%* greater than 12°F (6°C) 100%* Compressor Clutch Cycling Compressor clutch is cycled ON or OFF by the controller as needed to drive to or maintain the desired cab temperature setpoint. Heater Control Valve Heater control valve is opened or closed as needed to drive to or maintain the desired cab temperature setpoint.
Manual Override of Blower Control ● Blower speed remains in position selected by operator. ● Instrument Cluster Display no longer displays “Auto” for automatic. ● Temperature and mode door control remain automatic, but controller cannot use any speed beyond that selected to achieve the desired setpoint. ● Turning ATC switch OFF and then to “A” returns system to automatic operation. Maximum Cool Setting Selected ● Blower speed at 100%. ● Mode door to mid-cab vents ● Compressor runs continuously. The clutch is only cycled OFF when the freeze setting - 32° F (0° C) - is reached at the evaporator temperature sensor, and then ON again when temperature sensed warms to 37° F (3° C).
● Instrument Cluster Display no longer displays “Auto” for automatic. ● Moving the temperature control outside the maximum range returns the system to automatic control of compressor, blower and mode door. Maximum Heat Setting Selected ● Blower speed at 100%.* ● Mode door to floor vents. ● Heater control valve at full open position ● Instrument Cluster Display no longer displays “Auto” for automatic. ● Moving the temperature control outside the maximum range returns the system to automatic control of valve, blower and mode door. Exception * When heating is selected, blower speed remains at 25% until temperature sensed at evaporator exceeds 55° F (12.8° C).