Komatsu — STANDARD VALUE TABLE FOR CHASSIS RELATED PARTS

TESTING AND ADJUSTING STANDARD VALUE TABLE FOR CHASSIS RELATED PARTS STANDARD VALUE TABLE FOR CHASSIS RELATED PARTS PC09-1 20-3 (3) Applicable model PC09-1 Cate- gory Item Measurement conditions Unit Standard value for new machine Service limit value Engine speed 1 pump relief speed • Hydraulic oil temperature: 45 – 55°C • Engine water temperature: Min 60°C • 1 pump relief: bucket relief • 2 pump relief : bucket + arm relief rpm 2,010 1,600 2 pump relief speed 1,820 1,600 Spool stroke Boom control valve • Engine stop mm a b a b Arm control valve 17.0 6 6 17.0 6 6 Bucket control valve Swing control valve Arm control valve L.H. travel control valve R.H.

travel control valve Gauge control valve Travel 2-speed service control vave Travel of control lever and pedal stroke Boom control lever • Engine stop • Center of lever knob • Tip of pedal • Read max. value to end. of travel N → RAISE, LOWER 70 70 Arm control lever N → CURL, DUMP 70 70 Bucket control lever N → CURL, DUMP 70 70 Swing control lever N → Left, right swing 70 70 Boom swing con- trol lever N → Left, right boom swing 25 25 Blade control pedal N → RAISE, LOWER 45 45 Travel control lever N → FORWARD, REVERSE 65 65 Travel 2-speed control pedal Lo ↔ Hi — — Gauge control lever (variable gauge spec.) N → Extension, contraction — — Fuel control dial Min. ↔ Max.

45 45 Play of control lever Boom, Bucket Max. 25 Max. 25 Arm, Swing Max. 25 Max. 25