Lubrication and Service - Section 40 OM4051 Page 40-6 . Cleaning the Primary Element Only the primary elements may be cleaned, and then only if they are structurally intact. Do not reuse an element that is damaged. Do not clean and reuse the safety elements. Replace them with new parts if necessary. After inspection, determine the condition of the primary element. Choose either the washing method or compressed air method for cleaning the element. If the element is clogged with carbon, soot, oil and/or dust, the complete washing procedure will produce the best results. Wash elements with water and detergent as follows: FIGURE 40-6. INSPECTING THE FILTER ELEMENT 1.
Soak the element in a solution of detergent and water for at least 15 minutes. Rotate the element back and forth in the solution to loosen dirt deposits. Do not soak elements for more than 24 hours. Clean dust loaded elements with dry filtered compressed air as follows: 2. Rinse the element with a stream of fresh water in the opposite direction of normal air flow until rinse water runs clear. Maximum permissible water pressure is 276 kPa (40 psi). A complete and thorough rinse is essential. 1. Maximum nozzle pressure must not exceed 207 kPa (30 psi). The distance from the nozzle to the surface of the filter element must be at least 25 mm (1 in.) to prevent damage to the filter material. 3.
Dry the element thoroughly. If drying is done with heated air, the maximum temperature must not exceed 60°C (140°F) and must be circulated continually. Do not use a light bulb to dry elements. 2. As shown in Figure 40-7, direct the stream of air from the nozzle against the inside of the filter element. This is the clean air side of the element and air flow should be opposite of normal air flow. 4. After cleaning, inspect the element thoroughly for the slightest ruptures and damaged gaskets. A good method for detecting paper ruptures is to place a light inside the filter element, as shown in Figure 40-6, and inspect the outer surface of the filter element.
If holes or ruptures are found, do not reuse the element. Discard and replace with a new element. 3. Move the air flow up and down vertically with the pleats in the filter material while slowly rotating the filter element. 4. When cleaning is complete, inspect the filter element as shown in Figure 40-6. If holes or ruptures are noted, discard the element and replace with a new element. FIGURE 40-7. CLEANING THE FILTER ELEMENT WITH COMPRESSED AIR