GROUP 2 MODE SELECTION SYSTEM 1. POWER MODE SELECTION SYSTEM Main control valve Engine ECM Main pump Pilot pump Cluster CAN #1 Pump power shift EPPR MCU Drive signal Power mode pilot lamp Haptic controller CLUSTER AIRCON OFF Power mode switch signal CAN #1 & #2 CAN #2 900L5MS14 Mode selection system (micro computer based electro-hydraulic pump and engine mutual control system) optimizes the engine and pump performance. The combination of 3 power modes (P, S, E) and acceleration mode (10 set) of haptic controller makes it possible to use the engine and pump power more effectively corresponding to the work conditions from a heavy and great power requesting work to a light and precise work.
Power shift (Standard/Option) can be changed by "Service menu" in "Management" on the cluster. (~*) :
Load 5-3 Power mode Application U Engine rpm Power shift by EPPR valve Standard Option Standard Option nload Load Unload Load Current (mA) Pressure (kgf/cm2) Current (mA) Pressure (kgf/cm2) P Heavy duty power 175 0±50 1850±50 1850±50 1850±50 280±30 8 (~3) 230±30 0 (0) S Standard power 165 0±50 1750±50 1800±50 1800±50 305±30 10 (~5)±3 260±30 0 (0) E Economy operation 155 0±50 1650±50 1600±50 1750±50 340±30 13 (~8)±3 340±30 5±3 (0) AUTO DECEL Engine 100 deceleration 0±100 - 1000±100 - 700±30 38±3 700±30 38±3 One touch decel Engine quick 85 deceleration 0±100 - 850±100 - 700±30 38±3 700±30 38±3 KEY START Key switch 85 start position 0±100 - 850±100 - 700±30 38±3 700±30 38±3