Kaiyi — 14. MONITORING SYSTEM

(2) Mode setup ① Work tool 210WF3CD108 A B 290F3CD253 290F3CD254 · - Select on installed optional attachment A : It can set the user's attachment. It is available in setting #1~#10. B : Max flow - Set the maximum flow for the attachment. Relief pressure - Set the relief pressure. - U mode power ② One touch decel & low idle : 850 rpm 210WF3CD111 · Engine high idle rpm, auto idle rpm and pump torque (power shift) can be modulated and memorized sepa- rately in U-mode. U-mode can be activated by user mode switch. 290F3CD112 · Auto power boost ③ 210WF3CD118 290F3CD117 · The power boost function can be activated or cancelled.

Enable - The digging power is automatically increased as working conditions by the MCU. It is operated max 8 seconds. Disable - Not operated. 5-99 Step ( ) Engine speed (rpm) Idle speed (rpm) Power shift (bar) 1 1450 800 0 2 1500 850 3 3 1600 900 6 4 1700 950 9 5 1750 1000 (auto decel) 12 6 1800 1050 16 7 1850 1100 20 8 1900 1150 26 9 1950 1180 32 10 2000 1200 38