Kaiyi — 14. MONITORING SYSTEM

5-115 8)SELF DIAGNOSIS FUNCTION (1)Diagnostic methods :

Diagnostic information window, select (2)Diagnostic indication (Displays fault) Fault code Description Fail safe function F01 Ambient temperature sensor open 20˚C alternate value control F02 Ambient temperature sensor short F03 Cab inside temperature sensor open 25˚C alternate value control F04 Cab inside temperature sensor short F05 Evaporate temperature sensor open 0˚C alternate value control F06 Evaporate temperature sensor short F07 Null - F08 Null - F09 Mode 1 actuator open/short The alternate value is face F10 Mode 1 actuator drive circuit malfunction If not, the alternate value is Def/Foot F11 Intake actuator open/short The alternate value is air recirculation F12 Intake actuator drive circuit malfunction The alternate fresh air F13 Temperature actuator open/short If opening amount is 0 %, the alternate value is 0 % F14 Temperature actuator drive circuit malfunction If not, the alternate value is 100 % F15 Null - F16 Null -