Kaiyi — 2. HYDRAULIC AND MECHANICAL SYSTEM

3. HYDRAULIC SYSTEM HYDRAULIC OIL IS CLOUDY 1) HYDRAULIC OIL TEMPERATURE HAS RISEN ABNORMALLY 2) 6-7 YES Drop hydraulic oil sample on hot plate and check if foams come up. NO Cause Remedy Water is mixed. Air is intruded. Put hydraulic oil still, separate water and dispose it or replace hydraulic oil. Check suction line and return line and eliminate the air intruding source. NO Is hydraulic oil volume proper? YES Is oil cooler clogged and is bypass check YES valve always open? YES Is fan belt tension proper? NO NO Is not the set YES pressure of main relief, port relief ⓐ and travel relief Is main relief valve lower than valve used very YES the standard NO often? level?

Cause Remedy Oil cooler clogged. Bypass check valve is defective. ⓐ Replenish specified oil to the standard level. Clean oil cooler. Replace Adjust belt tension or replace belt. Readjust set pressure. Reduce load. Is main relief valve used very YES Is main relief valve used very and travel relief valve lower than the standard level? NO often?