Kaiyi — 2. HYDRAULIC AND MECHANICAL SYSTEM

MACHINE RUNS RECKLESSLY ON A SLOPE 6) 6-16 5) TRAVEL ACTION IS POWERLESS (travel only) Cause YES ⓐ Is travel motor's YES drain rate within standard level? Is travel brake Travel motor is YES NO pressure within faulty. standard level? Is travel relief valve pressure Travel brake valve NO within standard is defective. level? Travel relief valve NO is faulty. YES Hydraulic circuit Does parking that releases brake piston travel parking Increases Remove parking move lightly by brake is clogged brake spring in hand? with dirt. travel motor, Parking brake draw out piston ⓐ NO completely, refit piston in travel cover and check motor is stuck. if travel power changes.

Remains Travel reduction unchanged unit is defective. Cause Remedy ⓐ Travel motor is faulty. Travel brake valve is defective. Travel relief valve is faulty. Hydraulic circuit that releases travel parking brake is clogged with dirt. Parking brake piston in travel motor is stuck. Travel reduction unit is defective. Disassemble and repair. Disassemble and repair or replace. Disassemble and repair or replace. Disassemble and clean. Disassemble and repair. Disassemble and repair. Travel brake valve (counterbalance valve) is faulty. Cause Remedy Disassemble and repair or replace.