Kaiyi — 4. MECHATRONICS SYSTEM

7. Malfunction of pump 3 pressure sensor Before carrying out below procedure, check all the related connectors are properly inserted. 1) INSPECTION PROCEDURE 6-51 YES YES Check voltage YES between CN-1 (7)-GND eck voltage Spec : 1~5V tween CN-52 NO Check voltage Actuator operating ) - GND YES between CD-44 c : 1~5V (A)-(C) ator operating TEST 11 Spec : 24±2V Starting switch : ON Check voltage NO between CN-1 NO (4)-(6) Spec : 24±2V Starting switch :

ON NO Cause Remedy Defective MCU Short circuit or poor connection between CN-52- (32)-CN-1 (7) Detective P3 pressure sensor Short circuit or poor connection between CN-1 (7)-CD-44 (B) Short circuit or poor connection between CD-44 (A)-CN-1 (4) or CD-44 (C)-CN-1 (6) Short circuit or poor connection between CN-1 (4)-CN-51 (3) or CN-1 (6) - CN-51 (13) Replace Replace or repair Replace or repair Replace or repair Replace or repair Replace or repair ing di ag ram CN-51 CD-44 SENSOR 24V 3 4 A SUPPLY 7 B SIG GROUND(SENSOR) 13 6 C RETURN PUMP 3 PRESSURE SENSOR MCU CN-1 P3 PRESSURE SENSOR 32 CN-52 900L6MS39 900L6MS39