8. Malfunction of Negative 1 pressure sensor · Fault code : HCESPN 123, FMI 0~4 Before carrying out below procedure, check all the related connectors are properly inserted. 1) INSPECTION PROCEDURE Wiring diagram CN-51 SENSOR 24V 3 4 CD-70 A SUPPLY 1 B SIG GROUND(SENSOR) 13 6 NEGATIVE 1 PRESSURE SENSOR C RETURN MCU CN-1 N1 PRESSURE SENSOR 33 CN-52 900L6MS41 6-53 YES YES Check voltage YES between CN-1 (1)-GND eck voltage Spec : 1~5V tween CN-52 NO Check voltage Actuator operating ) - GND YES between CD-70 c : 1~5V (A)-(C) ator operating TEST 12 Spec : 24±2V Starting switch : ON Check voltage NO between CN-1 NO (4)-(6) Spec : 24±2V Starting switch :
ON NO Cause Remedy Defective MCU Short circuit or poor connection between CN-52- (33)-CN-1 (1) Detective N1 pressure sensor Short circuit or poor connection between CN-1 (1)-CD-70 (B) Short circuit or poor connection between CD-70 (A)-CN-1 (4) or CD-70 (C)-CN-1 (6) Short circuit or poor connection between CN-1 (4)-CN-51 (3) or CN-1 (6) - CN-51 (13) Replace Replace or repair Replace or repair Replace or repair Replace or repair Replace or repair