9. Malfunction of Negative 2 pressure sensor · Fault code : HCESPN 124, FMI 0~4 Before carrying out below procedure, check all the related connectors are properly inserted. 1) INSPECTION PROCEDURE Wiring diagram CN-51 CD-71 SENSOR 24V 3 4 A SUPPLY GROUND(SENSOR) 13 6 2 B C SIG RETURN NEGATIVE 2 PRESSURE SENSOR MCU CN-1 N2 PRESSURE SENSOR 17 CN-52 900L6MS43 6-55 YES YES Check voltage YES between CN-1 (2)-GND eck voltage Spec : 1~5V tween CN-52 NO Check voltage Actuator operating ) - GND YES between CD-71 c : 1~5V (A)-(C) ator operating TEST 13 Spec : 24±2V Starting switch : ON Check voltage NO between NO CN-1(4)-(6) Spec : 24±2V Starting switch :
ON NO Cause Remedy Defective MCU Short circuit or poor connection between CN-52- (17)-CN-1 (2) Detective N2 pressure sensor Short circuit or poor connection between CN-1 (2)-CD-71 (B) Short circuit or poor connection between CD-71 (A)-CN-1 (4) or CD-71 (C)-CN-1 (6) Short circuit or poor connection between CN-1 (4)-CN-51 (3) or CN-1 (6) - CN-51 (13) Replace Replace or repair Replace or repair Replace or repair Replace or repair Replace or repair