Kaiyi — 4. MECHATRONICS SYSTEM

10. Malfunction of Swing pressure sensor · Fault code : HCESPN 135, FMI 0~4 Before carrying out below procedure, check all the related connectors are properly inserted. 1) INSPECTION PROCEDURE Wiring diagram CN-51 SENSOR 24V 3 CD-24 A SUPPLY B SIG GROUND(SENSOR) 13 SWING PRESSURE SENSOR C RETURN MCU SWING PS 17 CN-52 900L6MS45 6-57 YES ck voltage YES een CN-52 - GND : 1~5V r operating Check voltage ST 14 between CD-24 NO (A)-(C) Spec : 24±2V Starting switch :