Kaiyi — 4. MECHATRONICS SYSTEM

11. Malfunction of ARM IN/OUT & bucket in pressure sensor · Fault code : HCESPN 133, FMI 0~4 Before carrying out below procedure, check all the related connectors are properly inserted. 1) INSPECTION PROCEDURE Wiring diagram CN-51 CD-35 SENSOR 24V 3 A SUPPLY GROUND(SENSOR) 13 B C SIG RETURN ARM IN/OUT & BUCKET IN PRESSURE SENSOR MCU ARM IN/OUT BUCKET IN PS 14 CN-52 900L6MS47 6-59 YES ck voltage YES een CN-52 - GND : 1~5V or operating Check voltage ST 15 between CD-35 NO (A)-(C) Spec : 24±2V Starting switch :

ON NO Cause Remedy Defective MCU Detective arm in/ out & bucket in pressure sensor Short circuit or poor connection between CN-52 (14)-CD-35 (B) Short circuit or poor connection between CD-35 (A)-CN-51 (3) or CD-35 (C)- CN-51 (13) Replace Replace or repair Replace or repair Replace or repair