Kaiyi — 4. MECHATRONICS SYSTEM

12. Malfunction of BOOM up pressure sensor · Fault code : HCESPN 127, FMI 0~4 Before carrying out below procedure, check all the related connectors are properly inserted. 1) INSPECTION PROCEDURE Wiring diagram CN-51 SENSOR 24V 3 CD-32 A SUPPLY B SIG GROUND(SENSOR) 13 BOOM UP PRESSURE SENSOR C RETURN MCU BOOM UP PS 19 CN-52 900L6MS49 6-61 YES ck voltage YES een CN-52 - GND : 1~5V or operating Check voltage ST 16 between CD-32 NO (A)-(B) Spec : 24±2V Starting switch :

ON NO Cause Remedy Defective MCU Detective boom up pressure sensor Short circuit or poor connection between CN-52 (19)-CD-32 (B) Short circuit or poor connection between CD-32 (A)-CN-51 (3) or CD-32 (C)- CN-51 (13) Replace Replace or repair Replace or repair Replace or repair