Kaiyi — 1. OPERATIONAL PERFORMANCE TEST

12) CONTROL LEVER STROKE (1) Measure each lever stroke at the lever top using a ruler. When the lever has play, take a half of this value and add it to the measured stroke. (2) Preparation Keep the hydraulic oil temperature at 50 ± 5 C. (3) ① ② Measurement Stop the engine. Measure each lever stroke at the lever top from neutral to the stroke end using a ruler. Repeat step ② three times and calculate the average values. ③ (4) Evaluation Unit : mm 7-15 T he measured drift should be within the fol lowing specifications. Model Kind of lever Standard Maximum allowable Remarks HX900 L Boom lever 90±10 115 Arm lever 90±10 115 Bucket lever 90±10 115 Swing lever 90±10 115 Travel lever 142±10 178