Kaiyi — 1. OPERATIONAL PERFORMANCE TEST

Unit : kgf / cm 2 ( ) : Power boost 7-20 1 7) SYSTEM PRESSURE REGULATOR RELIEF SETTING (1)Preparation ① Keep the hydraulic oil temperature at 50±5˚C. (2) Measurement ① Select the following switch positions. ·Power mode switch : P mode ② Slowly operate each control lever of boom, arm and bucket functions at full stroke over relief and measure the pressure. ③ In the swing function, place bucket against an immovable object and measure the relief pressure. ④ In the travel function, lock undercarriage with an immovable object and measure the relief pressure.

(3) Evaluation Pressure sensor a2 Main pump a1 Monitoring (analog) Cluster 900L7MS11 Pressure sensor a2 Main pump a1 Monitoring (analog) Cluster 900L7MS11 The average measured pressure should be within the following specifications. Model Function to be tested Standard Port relief setting HX900 L Boom 330(360)±10 380 Arm 330(360)±10 380 Bucket 330(360)±10 380 Travel 350±10 350 Swing 300±10 300