(3) Boom down (recycling) When the boom 1 and 2 spool is pushed to the right by the pilot pressure of port Pb3 and Pb7, the neutral passage (R1, L1) is closed, the oil discharged from pump P2 flows into the port B3 and B7 via parallel passage (R3, L3) and the load check valve (S3-1, S7-1). At the same time, as the port pc2 is pressurizing, the spool (AD3) of anti-drift valve is pushed up, the pressure of spring chamber (AD5) is released and the poppet (AD1) is opened and then the oil from port A3 and A7 flows into the tank passage (Ta). Some of returned oil makes the poppet (S7-3) inside boom 1 spool to open and is connected to the passage (S7-2) and flows together into the port B7.
This prevents the cavitation of cylinder rod side. AD1 AD2 A3 B3 pc2 AD5 AD4 AD3 S3-1 DR2 Ta L3 BOOM2 Pb3 Pa3 L1 6 S7-3 R1 BOOM1 Pb7 Pa7 Ta Ta R3 AD5 S7-2 DR2 AD4 S7-1 AD3 A7 B7 pc2 AD1 AD2 8007A2MC07 2-31 a