Komatsu — CHECK BEFORE STARTING

. LOADING SHOVEL MAINTENANCE MAINTENANCE CHECK BEFORE STARTING Check Oil Level in Hydraulic Tank, Add Oil WARNING may cause burns. Wait for the 7 - 16 temperature to go down before starting the work When removing the oil fi ller cap, turn it slowly to release th e internal pressure, then remov 1. Set the work equipm ent in the posture shown in the d iagram on the right, then check the oil level and add oil if nece ssary. wn in the ine at low 2.

If the work equipme diagram on the right nt is not in the condition sho , start the engine, run the eng , start the engine, ru speed, retract the a rm and bucket cylinder rods fully, then lower the boom, set t he bucket teeth in contact with t he ground, and stop the engine. after stopping the engine, move each 3. Within 15 seconds control lever (for wor k equipment and travel) to the full stroke in all directions to rel ease the internal pressure. 4. Open cover (1) on th e left side of the machine and c heck sight gauge (G). The oil le vel should be between the H an d L marks. NOTICE Do not add oil if the level is a bove the H line.

This will damage t he hydraulic equipment and cause the o il to spurt out.