Coolant Recommendations and Specifications QSC8.3 and QSL9 Page V-16 Section V - Maintenance Specifications Fully formulated antifreeze must be mixed with good- quality water at a 50/50 ratio (40- to 60-percent working range). A 50/50 mixture of antifreeze and water gives a -36°C [-33°F] freezing point and a 108°C [226°F] boiling point, which is adequate for locations in North America. The actual lowest freezing point of ethylene glycol antifreeze is at 68 percent. Using higher concentrations of antifreeze will raise the freezing point of the solution and increase the possibility of a silica gel problem.
Legend 1 Freezing Point Temperature Scale 2 Boiling Point Temperature Scale A refractometer must be used to measure the freezing point of the coolant accurately. Use Cummins Filtration™ refractometer, Part Number CC2800 or CC2806.