MAN Nutzfahrzeuge — Connector designation: LDF 1 Reference ground: GND 0 (13)

98 Plug connection: 54 Function group: Analog input Connector designation: HGB 1 Reference ground: GND 0 (13) Description of input Characteristic parameter Conditions Dim. Min. Typ. Max. EMC capacitor Input resistance Idle speed voltage Input filter Input voltage Evaluation range Data acquisition accu- racy DU from input pin in up to number of pro- cessors C EMC R in U LL t U inz F abs U in R =0W Gen U is in range of U in inz nF kW V m s V % 1.2 2.0 0.9 0.1 1.5 2.05 U R 1.5 2.2 2.1 2.1 U –0.1 R ±2.5 Remarks: Plug connection: 36 Function group: Analog input Connector designation: LDF 1 Reference ground: GND 0 (13) Description of input Characteristic parameter Conditions Dim. Min. Typ. Max.

EMC capacitor Input resistance Idle speed voltage Input filter Input voltage Evaluation range Data acquisition accu- racy DU from input pin in up to number of pro- cessors C EMC R in U LL t U inz F abs Range U in R =0W Gen U is in range of U in inz nF kW V m s V % 1.2 96 43 0.1 1.5 100 GND 0 73 2.2 104 100 U –0.1 R +1.3 –2.0 Remarks: – The data acquisition accuracy is based on radiometric signal processing with sensor supply LDF2 (at LDF 2= U ) R – The data acquisition accuracy was determined by quadratic addition of individual faults