MAN Nutzfahrzeuge — MAN-Cats - Software Description

MAN-Cats – Software Description After this stage, the contents of the fault memory are shown first (see screenshot below). Fault description: : too great ў measured value too high : too small ў measured value too low : no signal ў possible line break, sensor faulty ? : implausible ў unknown fault J : saved ў fault has been stored n : present ў fault exists at present ~ : sporadic ў momentary fault Frequency: Depending on the channel, the EDC counts the faults from 1 to 40 or 1 to 210. If the fault is no longer present when ignition is switched back on again, the frequency of the fault is reduced by 1. (Our example therefore shows 3 faults which were present at least once).

Peripheral conditions: shows other important channels as additional information, e.g. the engine speed at which the fault occurred and the magnitude of the fault. Once the fault memory has been examined and noted, press “Enter” to go the submenu where you select the “Bus” function. 72