2. General information The control unit must be connected in accordance with circuit diagram 51.17099-8087 together with the assemblies belonging to the system. If not otherwise specified, all inputs and outputs are short-circuit-proof to ground and +U batt 28 V, T U 65 ° C. Operation without the battery is not permitted. The control unit may be damaged as the result of the increased power loss in the event of a short-circuit in more than two plug connections against on another or against the supply voltage. Supply voltages and ground connections are not short-circuit-proof and are not protected against polarity reversal.
If not otherwise specified, all values apply in the temperature and voltage range as specified by TKU. Control unit supply: BATT+ across pin 15, 16 (connected internally, must be connected externally) BATT– across pin 18, 19 (connected internally, must be connected externally) The time constant values t apply at an internal alternator resistance of 0 W . The current directions are defined in accordance with the load count system: Positive currents flow into the control unit. Negative currents flow out of the control unit. If not otherwise specified, the working range for analog inputs is from 0 .. U R . Data acquisition accuracy is always referred to U Rnominal =5.000V 95