TESTING AND ADJUSTING TESTING CLEARANCE OF SWING CIRCLE BEARING RELEASING REMAINING PRESSURE IN HYDRAULIC CIRCUIT # If the piping between the hydraulic cylinder and the control valve is disconnected, release the remaining pressure from the circuit as follows. The travel circuit is an open circuit, so there is no remaining pressure. It is enough to remove the oil filler cap. 1. Loosen the oil filler cap slowly to release the pressure inside the tank. 2. Operate the control levers. When the levers are operated 2 – 3 times, the pressure stored in the accumula- tor is removed. 3. Start the engine, run at low idling for approximately 5 minutes, then stop the engine and operate the control levers.
Repeat the above operation 2 – 3 times to release all the remaining pressure. TESTING CLEARANCE OF SWING CIRCLE BEARING 1. Method of testing clearance of swing circle bearing when mounted on machine. a. Fix a magnet-type dial gauge to the outer circle (or inner circle) of the swing circle, and put the tip of the probe in contact with the inner circle (or outer circle). Set the dial gauge at the front or rear. b. Extend the work equipment to the maximum reach, and set the tip of the bucket to the same height as the bottom of the revolving frame. When this is done, the upper structure will tilt for- ward, so the front will go down and the rear will rise. c.
Set the dial gauge to the zero point. d. Set the arm more or less at right angles to the ground surface, then lower the boom until the front of the machine comes off the ground. When this is done, the upper structure will tilt back, so the front will rise and the rear will go down. e. Read the value on the dial gauge at this point. The value on the dial gauge is the clearance of the swing circle bearing. When carrying out the measurement, do not put your hand or feet under the undercarriage. f. Return to the condition in Step b., and check that the dial gauge has returned to the zero point. If it has not returned to the zero point, repeat Steps b. To e. 20-57