TESTING AND ADJUSTING POINTS TO REMEMBER WHEN CARRYING OUT MAINTENANCE TROUBLESHOOTING ii. Defective crimping or soldering of connec- tors. The pins of the male and female con- nectors are in contact at the crimped terminal or soldered portion, but if there is excessive force brought to bear on the wiring, the plat- ing at the joint will peel and cause improper connection or breakage. iii. Disconnections in wiring. If the wiring is held and the connectors are pulled apart, or com- ponents are lifted with a crane with the wiring still connected, or a heavy object hits the wir- ing, the crimping of the connector may sepa- rate, or the soldering may be damaged, or the wiring may be broken. iv.
High-pressure water entering connector. The connector is designed to make it difficult for water to enter (drop-proof structure), but if high-pressure water is sprayed directly on the connector, water may enter the connec- tor, depending on the direction of the water jet. Since the connector is designed to pre- vent water from entering, but at the same time, if water does enter, if it difficult for it to be drained. Therefore, if water should get into the connector, the pins will be short- circuited by the water, so if any water gets in, immediately dry the connector or take other appropriate action before passing electricity through it. 20-63