Komatsu — E- 6 [E315] Abnormality (short circuit) in battery relay output system is displayed

TROUBLESHOOTING E-MODE E-6 [E315] Abnormality (short circuit) in battery relay output system is displayed # This troubleshooting is carried out when there is still an abnormality, so when disconnecting the connector and inserting the T-adapter, or when removing the T-adapter and returning the connector to its original position, if the service code E is not displayed, the problem has been removed. Check with the engine stopped (push the fuel control lever of the fuel injection pump to the NO INJECTION position). # Before carrying out troubleshooting, check that all related connectors are properly inserted. # Always connect any disconnected connectors before going on to the next step.

# This only occurs when the engine is stopped and the starting switch is turned OFF. E-6 Related electric circuit diagram Engine throttle pump controller 20-119 YES 1 Is resistance between C01 (female) (1) and 2 YES chassis normal? Is resistance between • Between C01 C01 (female) (1) and bat- (female) (1) and NO tery relay terminal BR, and between wiring har- chassis: Approx. ness and chassis normal? 110X • Turn starting switch • Between C01 NO OFF. (female) (1) and • Disconnect C01. battery relay BR: Max 1X • Between wiring harness and chassis: Min. 1 MX • Turn starting switch OFF. • Disconnect C01 and battery relay BR.

Cause Remedy Defective engine throttle, pump controller Defective battery relay 1) Contact between other wiring harnees and wiring harness between C01 (female) (1)-H02 (9)- battery relay BR. 2) When light is connected Replace Replace Replace