Komatsu — E- 12 Defective operation of battery relay system (engine does not stop)

TROUBLESHOOTING E-12 E-12 Defective operation of battery relay system (engine does not stop) # This only occurs when the engine is stopped and the starting switch is turned OFF. Check with the engine stopped (push the fuel control lever of the fuel injection pump to the NO INJECTION position). # Before carrying out troubleshooting, check that all the related connectors are properly inserted. # Always connect any disconnected connectors before going on the next step. battery relay BR. Note 1: When the starting switch is ON, the controller end is OFF, but a voltage of approx. 20 - 30V is always from starting switch BR, so if the voltage is measured at C01 (1), there is a voltage of 20 - 30V.

20-133 YES 1 Is E315 displayed? YES Relay drive signal 2 • Turn starting switch Is display of monitor- ON. NO ing code 35 as shown 2 YES in Table 1? Is resistance between • Turn starting switch C01 (female) (1) and bat- OFF. tery relay terminal BR, • 20 - 30V NO and between wiring har- ness and chassis normal? • Between C01 (fe- NO male) (1) and battery relay BR: MAX. 1 q • Between wiring har- ness and chassis: Max. 1 Mq • Turn starting switch OFF. Cause Remedy See E-6 Defective engine throttle, pump controller Defective battery relay Disconnection in wiring harness between C01 (female) (1) - battery relay BR When light is connected - Replace Replace Replace