Komatsu — ACTION TAKEN BY CONTROLLER WHEN ABNORMALITY OCCURS AND PROBLEMS ON MACHINE

TROUBLESHOOTING C-MODE Condition when normal (voltage, current, resistance) Action by controller when abnormality is detected Problem that appears on machine when there is abnormality Between C03 (13) and (16): 0.5 - 4.5 V Between C03 (6) and (16): 18 - 28 V Between C03 (female) (13) and (16), (13) and chassis Resistance: No continuity (Disconnect connectors C03 and C07) 1. Takes front pump pressure as 0 MPa (0 kg/cm 2 ) when actuating # If the abnormality is restored by the vibration of the machine, it resets the power source to restore to the proper condition. (However, the service code display does not go out).

The travel speed does not auto- matically shift (it does not change from Hi to Lo) # If the button is operated manually, the panel display is switched. Voltage between C03 (6) and (16): 18 -28 V Takes front pump and rear pump pres- sure as 0 MPa (0 kg/cm 2 ) when actuat- ing The travel speed does not auto- matically shift (it does not change from Hi to Lo) # If the button is operated manually, the panel display is switched) Resistance: 500 - 1000 W Voltage (AC range): 0.5 - 3.0 V (engine started) It functions in the equivalent of the G/O mode (the speed rises) It operates about the same as G/O mode (prolix) (the power is slightly lower) 20-167