Komatsu — H- 5 Auto- deceleration does not work (when PPC shuttle valve)

TROUBLESHOOTING H-MODE H-4 Abnormal noise generated (around pump) H-5 Auto-deceleration does not work (when PPC shuttle valve) # The control pressure for the travel and swing passes through the PPC shuttle valve and is supplied to the pressure switch. 20-215 3 YES Go to 4 Do bubbles YES disappear when engine is stopped? 2 NO YES Are there bubbles inside hydraulic tank? YES 1 4 Is suction strainer Is hydraulic tank oil clogged by external level normal? NO objest? 5 YES Is suction strainer • External object: clogged with metal Cloth, etc. particles or are metal NO particles stuck to drain plug?

NO NO Cause Remedy Improper hydraulic oil Clogged by external object (cloth, etc.) Defect inside pump Operate for a short time and watch for any change in symptoms Lack of hydraulic oil Change hydraulic oil Remove Repair or replace Inspect again (depending on changes in symptoms) Add hydraulic oil 1 YES Does condition become normal when pressure switch is replaced? NO Cause Remedy Defective pressure switch Defective operation of PPC shuttle shuttle valve with travel PPC calve Replace Repair or replace