Komatsu — M- 8 When starting switch is turned ON (engine stopped), basic check items flashes

TROUBLESHOOTING M-CODE c) (hydraulic oil level) flashes # Check that the hydraulic oil is at the specified level before carrying out troubleshooting Table M-8 c) Related electric diagram Engine throttle, pump controller 20-253 YES 1 Does display go out 3 YES when P09 (female) (1) is connected to Is bit (5) of chassis ground? YES monitoring code 24 2 lighted up? • Disconnect P09. • Turn starting switch Is continuity between ON. C16 (female) (9) and • Turn starting NO chassis as shown in NO switch ON. table? • Set to monitoring • Turn starting code 24. switch OFF. NO • Disconnect C16,P09. * ConnectrRdisconnect short connector to P09(female) (1).

Cause Remedy Defective hydraulic oil level sensor system (see M-29) Defective governor, pump controller Defective monitor panel Defective contact, or disconnection in wiring harness between C16 (female) (9) - P09 (female) (1) - Replace Replace Repair or replace Chassis ground Continuity Connected Yes Disconnected No