Komatsu — SELF- REDUCING PRESSURE VALVE

STRUCTURE AND FUNCTION SAFETY-SUCTION VALVE FOR SERVICE VALVE 4. When there is abnormal high pressure. a. When pressure PR of the self-reducing pressure valve becomes abnormally high, ball (10) pushes against the force of spring (9), separates from the seat, and allows hydraulic oil to flow from output port PR ЖЖ T , so pressure PR goes down. This action protects the equipment at the desti- nation for the hydraulic pressure supply (PPC valve, electromagnetic valve, etc.) from abnormally high pressure. (See figure at the right). 10-49