Hydraulic Brake System, Bosch 42.15 General Information 3 2 4 7 8 5 6 1 9 10 11 12 13 14 15 A 05/09/2003 NOTE: Not all parts are shown. A. DOT 3 Brake Fluid f420376a 1. Secondary Compensating Valve (open) 2. Secondary Reservoir Section 3. DOT 3 Brake Fluid Reservoir 4. Piston Stop 5. Primary Reservoir Section 6. Primary Compensating Valve (open) 7. Power Brake Booster Assembly 8. Frontwall 9. Primary Pressure Chamber 10. Primary Piston/Actuator Assembly 11. Primary Piston Return Spring 12. Secondary Piston/Actuator Assembly 13. Secondary Pressure Chamber 14. Housing 15.
Secondary Piston Return Spring The "R" light (brake pressure) output—terminal 3—is activated when any of the following conditions exist: Fig. 5, Master Cylinder Too much electrical resistance in the backup pump motor. This is often caused by a bad ground.
The flow switch on the power brake booster closes due to reduced or lost flow of ATF to the power brake booster; Monitor Module Terminal Identification The pressure differential switch on the master cylinder closes due to a pressure difference between the front and rear brake subsystems; Terminal Number Function Circuit Number 1 Not Used The DOT 3 brake fluid level switch on the mas- ter cylinder reservoir closes due to a drop in the fluid level; 2 Not Used 3 Light "R" (Brake System Pressure) Output 388H Business Class M2 Workshop Manual, Supplement 5, September 2003 050/5