Freightliner — Freightliner Business Class M2 Workshop Manual

Service Brake Chambers, Haldex 42.16 Operating and Leakage Tests NOTE: For both of these tests, the air system must be pressurized to at least 80 psi (550 kPa). Operating Test 1. Chock the tires. 2. Apply the brakes. Check that each piston rod moves out promptly, without binding. 3. Release the brakes. Check that each piston rod returns to the released position promptly, without binding. 4. Check the brake chamber stroke. It should be as short as possible without causing the brakes to drag. If needed, adjust the travel of the piston rod at the slack adjuster. For instructions, refer to the foundation brake section in this manual. Leakage Test 1.

Apply the brakes and hold them on full line pres- sure of at least 80 psi (550 kPa). 2. Using a soap solution, coat the clamp ring. Leak- age is excessive if it produces a 1-inch (25-mm) bubble within five seconds. CAUTION Don’t overtighten the clamp ring. This can distort the flange sealing surface, or the clamp ring it- self. 3. If the leakage is excessive, tighten the clamp ring flange nuts evenly until the leakage is re- duced. For acceptable torque ranges, see Speci- fications 400 . 4. Using a soap solution, coat the area around the piston-rod hole. No leakage is permitted. If there is leakage, replace the diaphragm. For instruc- tions, see Subject 110 .

Business Class M2 Workshop Manual, Supplement 0, January 2002 100/1