Air Reservoir Automatic Drain Valve, Bendix DV–2 42.18 General Information General Information 1 2 The DV-2 automatic reservoir drain valve automati- cally ejects moisture and contaminants from the res- ervoir in which it is connected. If operates automati- cally and requires no manual assistance or control lines from other sources. 3 The automatic reservoir drain valve ( Fig. 1 ) has a die cast aluminum body and cover and is nomally mounted either in the bottom of the reservoir using the top port of the rain valve or in the end of an end drain reservoir using the side port of the valve. 4 5 The DV-2 is also available with a heater and thermo- stat ( Fig.
2 ) cast into the cover for vehicles operated in subfreezing temberatures. A 1/4-inch male pipe adaptor is supplied with all DV-2 drain valves, end drain and bottom drain, both standard and heated. This adaptor should be installed directly into the valve. 6 7 8 f420041a 09/26/94 1. Top Reservoir Port 2. Valve Body 3. Hexhead Nipple 4. Side Reservoir Port 5. Lockwasher (4 qty.) 6. Capscrew (4 qty.) 7. Valve Cover 8. Exhaust Port With no pressure in the system, the drain valve’s inlet and exhaust valves are closed. See Fig. 3 . Upon charging the system, a slight pressure opens the inlet valve which permits air and contaminants to collect in the sump. See Fig. 4 .
The inlet valve re- mains open when pressure is rising in the system until the air compressor cuts off, allowing the spring action of the valve guide in the sump cavity to close the inlet valve. The inlet valve and the exhaust valve are now both closed. See Fig. 5 . When the reservoir pressure drops approximately 2 psi (14 kPa), the air pressure in the sump cavity opens the exhaust valve and allows moisture and contaminants to be ejected from the sump cavity until pressure in the sump cav- ity drops sufficiently to close the exhaust valve. See Fig. 6 . Fig. 1, Standard DV-2 Valve 10/03/2001 f430277 Fig.
2, DV-2 Valve with Heater/Thermostat The length of time the exhaust valve remains open and the amount of moisture and contaminants ejected depends upon the sump pressure and the wet tank pressure drop that occurs each time air is used from the system. 05/25/2005 f421885 Fig. 3, No System Pressure Business Class M2 Workshop Manual, Supplement 0, January 2002 050/1