Air Reservoir Automatic Drain Valve, Bendix DV–2 42.18 Removal and Installation WARNING 5. Leak test the drain valve following the instruc- tions in Subject 110 . Before working on or around air brake systems and components, see Safety Precautions 100 . Failure to do so may result in personal injury. 6. Remove the chocks from the tires. Removal 1. Park the vehicle on a level surface and apply the parking brakes. Shut down the engine. Chock the tires. 2. Drain the air system. 3. If the DV-2 with heater/thermostat is installed, disconnect heater wire from the valve. 4. Remove the drain valve assembly from the end of the wet tank air reservoir. Installation IMPORTANT:
When installing a DV-2 drain valve equipped with a heater and thermostat, the #14 gauge lead wire on the valve should be con- nected to the ON position of the engine control or ignition switch. Use an 8 amp fuse for one valve, a 15 amp fuse for two valves, and a 20 amp fuse for three valves. All electrical connec- tions must be waterproof. 1. Using a cleaning solvent, thoroughly flush and clean the wet tank reservoir to avoid early fouling at the drain valve. Aerate the wet tank thoroughly if solvents were used during cleaning. 2.
Install the drain valve assembly on the wet tank by tightening the hexagonal nipple until the drain valve is positioned so that the valve body is par- allel to the bottom of the wet tank with the ex- haust port facing straight down. Make sure that the exhaust port is clear of any air, electric, or fuel lines. Make sure the drain valve is attached tight enough to prevent leakage. 3. If installing a DV-2 with heater/thermostat, con- nect heater wire. 4. Close the drain cocks to the supply and service reservoirs. Start the vehicle engine to pressurize the air system. Business Class M2 Workshop Manual, Supplement 0, January 2002 120/1