Freightliner — Freightliner Business Class M2 Workshop Manual

Air Management Unit 42.19 General Information Relay Valve 1 The relay valve ( Fig. 8 ) is a normally closed air valve that delivers system air pressure when the control pressure exceeds the specified level. There is one internal control port on the left side of the module that will mate with pressure switch "B" module ( Fig. 3 ) to receive parking brake air. The control, supply, and delivery ports are on the face of the module. 2 4 3 12/19/2001 f543861 1. External Supply Port 2. External Delivery Port 3. Pressure Adjustment Knob 4. Closed, Non-Thru Ports 5 4 4 Fig. 9, Regulator Module 12/19/2001 f543863 1. External Supply Port. 2. External Delivery Port 3. External Control Port 4.

Non-Thru Ports 5. Internal Control Port (Left-hand only) Fig. 8, Relay Valve 2 Regulator Module The adjustable regulator module ( Fig. 9 ) limits the pressure delivered from the valve to a manually se- lected or adjusted level. Any pressure below this level will be approximatley equal to the supply pres- sure. The adjustment knob on the module allows for the delivery pressure to be set between 0 and 120 psi (827 kPa) at 180 psi (1240 kPa) supply pressure. 1 3 12/19/2001 f543858 1. Non-thru Ports 2. Internal Pressure Protected Port 3. Non-thru Port Fig. 10, End Block A non-adjustable regulator is also available. This module will have a pre-set pressure that will be printed on the module.

End Block The ported end block module ( Fig. 10 ) contains ports that are used to deliver air to another AMU on the vehicle or to modules at the other end of the AMU. A non-ported end block is also available. Business Class M2 Workshop Manual, Supplement 1, April 2002 050/4 1 2 3