Air Management Unit 42.19 Troubleshooting AMU Diagnostics switch will be open regardless of pressure in the sec- ondary air system. This will cause the vehicle’s low air pressure warning lamp and buzzer to remain on even if both systems are fully charged. Pressure Switch "A" Testing Pressure Switch Module "A" contains pressure switches and, on the 12-18205-XXX version only, a 3-way shut-off valve. The shutoff valve allows the rest of the AMU modules and downstream compo- nents to be serviced without having to drain the air tanks.
Pressure Switch Module "A" comes in four different configurations (see Table 1 ) depending on whether the vehicle has air or hydraulic brakes and whether an air-horn/engine-fan pressure switch is needed. The internal pressure switches for part num- bers 12-18205-XXX have a diode wired in parallel with the switch. Internal pressure switches for part numbers A12-19776-XXX do not have diodes wired in parallel with the internal pressure switches. The air-horn/engine-fan pressure switch monitors air pressure in the secondary air system. The purpose is to prevent the air-horn/engine-fan solenoid from acti- vating when the system air pressure is too low.
This switch closes at approximately 87 ±7 psi (600 ±48 kPa). The stop lamp pressure switch monitors pressure in the service brake system. Its main purpose is to con- trol the stop lamps. This switch closes at approxi- mately 3.5 ±1.5 psi (24 ±10 kPa). The park brake status pressure switch monitors air pressure in the park brake system. This switch opens at approximately 70 ±5 psi (483 ±34 kPa) for module part numbers 12-18205-002 and -003. This switch opens at 77 ±7 psi (531 ±48 kPa) for module part numbers A12-19776-002, -003, -012, and -013. The low air pressure switches monitor the air pres- sure in the primary and secondary supply air sys- tems.
The pressure switches are internal to the Pres- sure Switch Module "A". The primary and secondary low air switches are wired in series. Each pressure switch closes when air pressure reaches approxi- mately 70 ±5 psi (483 ±34 kPa). When both systems have reached 70 psi (483 kPa) and both switches are closed, a circuit to ground is completed to the Chassis Module (CHM). On the 12-18205-xxx valve, the low air pressure switch on the secondary side senses secondary air pressure downstream of the shutoff valve. If the shutoff valve is off, the pressure The optional pressure switch monitors air pressure in the secondary air system. This switch can be used to control optional accessories.
This switch closes at approximately 70 ±5 psi (483 ±34 kPa). For complete troubleshooting of a system (i.e. low air pressure warning lamp), refer to the appropriate cov- erage in this manual. The following tests are compo- nent tests only and do not troubleshoot an entire system. Pressure Switch "A" Configurations Configuration Brake System Type No.
of Pressure Switches Pressure Switch Function Diagnostics Location 1 Air Brake 3 Low Air Warning (Primary Air) Low Air Warning (Secondary Air) Stop Lamp (Application Air) Low Air Warning (Primary Air) Pressure Switch "A" Tests (Air Brakes) 2 Air Brake 4 Low Air Warning (Secondary Air) Stop Lamp (Application Air) Air Horn/Engine Fan Business Class M2 Workshop Manual, Supplement 9, March 2006 300/1