Air Management Unit 42.19 Troubleshooting Air-Horn/Engine-Fan Pressure Switch Tests (Configurations 1 & 2 - Air Brakes) NOTE: If any test fails, the Pressure Switch Module A is defective and must be replaced. Air-Horn/ Engine-Fan Pressure Switch Diode Test Conditions Test Point Good Result If Test Fails: ·Drain air tanks. Resistance Check (or diode test if meter is capable): With the leads connected one way, the meter should read resistance (value not important), then when the leads are reversed the reading should be infinite or 0 ohms. Faulty Pressure Switch "A". ·Key OFF, Engine OFF. ·Pressure Switch "A" 6-way connector disconnected. Measured between pin E and F (switch side).
Then, reverse test leads and check again. Applies to part numbers 12-18205- XXX. For all other part numbers: Skip this test. NOTE: If the result is 0 ohms both ways, either the diode is shorted or the pressure switch is stuck closed. If the result was 0L ohms both ways, then the diode is open. Air-Horn/ Engine-Fan Pressure Switch ·Key OFF, Engine OFF. ·Pressure Switch "A" 6-way connector disconnected. Resistance Check: Less than 1 ohm (test leads both ways). Faulty Pressure Switch "A". Measured between pins E and F (switch side). Then, reverse test leads and check again. NOTE:
If the resistance is more than 1 ohm either way, then the air horn/engine fan pressure switch is not closing between 80 and 94 psi (551 to 648 kPa). ·Drain air tanks. ·Close the 3-way shut-off valve on the module. ·Disconnect the SEC port on the face of the module and connect a regulated air supply setup as in Fig. 1 to the port. ·Using the setup in Fig. 1 , close Valve "A" and Valve "B". Back the regulator screw off so that the downstream pressure is zero. Connect shop air to the test apparatus. Open Valve "A". Apply 100 psi (689 kPa) to the SEC port by adjusting the pressure regulator. This should cause the air horn/engine fan pressure switch to close.
Table 4, Air-Horn/Engine-Fan Pressure Switch Tests (Configurations 1 & 2 - Air Brakes) Business Class M2 Workshop Manual, Supplement 9, March 2006 300/4