Double Check Valve 42.20 General Information General Information The Bendix DC–4 shuttle-type double check valve ( Fig. 1 ) is normally used only when the vehicle is equipped with a trailer hand control valve. Double check valves are used in the air brake system to di- rect a flow of air into a common line from either of two sources, whichever is at the higher pressure. A shuttle type valve has a movable shuttle to seal off the lower pressure source and allow the air from the higher pressure source to flow. 1 In this case, the valve allows air to be supplied to the trailer brakes from either the hand control valve or the foot valve, whichever supplies the higher pres- sure.
This allows the trailer brakes to be applied with either the hand valve or the foot valve. If both the foot and hand valves are applied simultaneously, the DC–4 valve will supply air to the trailer brakes from whichever valve is applying higher pressure. 2 Principles of Operation 10/16/2001 f430278 1. Foot Brake Valve 2. Double Check Valve As pressurized air enters either end of the double check valve inlet port, the moving shuttle responds to the greater pressure source and seals the opposite port. The air flow continues out the delivery port of the valve. The position of the shuttle will reverse if the pressure levels are reversed.
Double check valves are designed so the shuttle cannot interfere with the backflow of air in the exhaust mode. Fig. 1, Brake Valve and Double Check Valve Plumbing Business Class M2 Workshop Manual, Supplement 0, January 2002 050/1