Quick Release Valve 42.21 General Information General Information When the front brake chambers are equipped with a QR–1 valve, it is located on the forward face of the crossmember just aft of the transmission. A delivery line from the foot valve is connected to the port on top of the QR–1 quick release valve; the two side ports are for brake chamber connections, and the exhaust port is located at the bottom of the valve. QR-1C Valve QR-1 Valve The function of the QR–1 quick release valve ( Fig. 1 ) is to speed up the release of air pressure from the front service brake chambers.
When the front brake chambers are equipped with a QR–1 valve, and a foot brake application is released, the exhaust port of the quick release valve opens and the air from the front brake chambers is exhausted through the quick release valve. This accelerates the release of the front brakes. The QR–1C quick release valve ( Fig. 2 ) is a dual function valve. Its primary function is to speed up the release of air pressure from the service brake cham- bers. Additionally, the valve works as an anti- compound device. The double check valve feature prevents a service and parking brake application from occurring at the same time.
1 The QR–1C valve is generally mounted on the axle and serves two spring brake actuators. A balance line from the relay valve delivery port is connected to the balance port on top of the QR–1C quick release valve. The two side ports are for brake chamber con- nections. The supply port is connected to the delivery port of the parking brake control valve, and the ex- haust port is located at the bottom of the valve. The air connections to the QR–1C are as follows: 2 2 3 5 1. The QR–1C delivery port is connected to the emergency port of the spring brake. 2. The QR–1C balance port is connected to the de- livery of the relay valve. NOTE:
The QR–1C valve should be connected to the delivery side (not to the service or signal side) of the relay valve. 4 6 3. The QR–1C supply port is connected to the de- livery of the park control valve. Principles of Operation QR-1 Valve 7 07/28/94 f420049a 1. Supply Port 2. Delivery Port 3. Exhaust Port 4. Diaphragm 5. Cover 6. O-Ring 7. Body When the foot brake control is applied, delivery air enters the brake valve port on the QR–1 quick re- lease valve; the diaphragm moves down, sealing the exhaust port. At the same time, air pressure forces the edges of the diaphragm down, allowing air to flow out the brake chamber ports, filling the cham- bers and applying the front axle brakes. Fig.
1, QR-1 Valve and Cross Section When the brake chamber air pressure (beneath the diaphragm) equals the air pressure being delivered Business Class M2 Workshop Manual, Supplement 0, January 2002 050/1