Freightliner — Freightliner Business Class M2 Workshop Manual

Tractor Protection Valve, Bendix TP–3DC 42.25 General Information 2 3 4 1 3 2 1 4 14 15 16 5 6 13 5 6 12 12 13 7 8 8 7 11 10 07/08/97 f421482a 11 10 9 9 1. Trailer Air Supply Valve 2. Tractor Supply Port 3. Auxiliary Supply Port 4. Trailer Supply Port 5. Single Check Valve 6. Trailer Control Port 7. Spring 8. Guide 9. Diaphragm (Double Check Valve) 10. Tractor Control Port (Primary) 11. Foot Valve 12. Double Check Valve 13. Tractor Control Port (Secondary) 14. Hand Valve 15. Stop Lamp Switch Port 16. Plunger 02/22/2000 1. Tractor Supply Port 2. Auxiliary Supply Port 3. Trailer Supply Port 4. Check Valve Spring 5. Check Valve 6. Trailer Control Port 7. Valve Spring 8. Guide 9.

Diaphragm (Double Check Valve) 10. Tractor Control Port (Primary) 11. Tractor Control Port(Secondary) 12. Stop Lamp Switch Port 13. Plunger f421487 Fig. 3, Initial Charge Fig. 2, TP-3DC, Sectional View With the inlet valve closed, air pressure from the brake foot or hand control valves will not reach the trailer control circuit when the brakes are applied. The air forces the diaphragm to seat, sealing off the tractor control primary port. The air then exits the valve at the tractor control (secondary) port and flows to the foot valve or hand valve where it is exhausted.

Anti-Compounding Tractor Protection If the red trailer air supply knob on the instrument panel is pulled out while the service brakes are ap- plied, the single check valve in the TP–3DC prevents simultaneous spring and service brake application. As pressure in the trailer supply circuit drops, the spring in the TP–3DC valve forces the inlet valve closed (as described above in "Tractor Protection." Any pressure in the trailer control circuit is relieved by passing first through the single check valve and then exhausting at the trailer supply valve. See Fig. 7 .

If the red trailer air supply knob on the instrument panel is pulled out (or if a large leak develops in the trailer supply circuit), pressure in the trailer supply circuit (and the auxiliary supply circuit, if used) is vented. See Fig. 6 . When pressure drops to about 20 to 30 psi (138 to 207 kPa), the pressure can no longer overcome the spring force inside the TP–3DC valve and the inlet valve closes. Business Class M2 Workshop Manual, Supplement 0, January 2002 050/2