Air Dryer, Meritor WABCO System Saver 1200 42.28 General Information and Principles of Operation 2 3 4 1 6 07/23/97 f421613 5 1. Heater/Thermostat Assembly 2. Desiccant Canister 3. Filter 4. Regeneration Valve Assembly 5. Exhaust Port (Purge Valve Assembly) 6. Pressure Relief Valve Fig. 2, Sectional View When the compressor reaches about 125 psi (862 kPa), the purge valve opens, allowing the initial de- compression of the dryer, and expelling the water and contaminants collected in the base of the dryer. The regeneration valve, along with the pressure- controlled check valve, allows the system air to flow back through the dryer. This back flow dries the des- iccant for the next cycle.
Business Class M2 Workshop Manual, Supplement 6, September 2004 050/2