AD-IS Air Dryer, Bendix 42.33 Delivery Check Valve and Governor Replacement 9. Install the adaptor fitting into the governor. Using the silicone grease, lubricate the remaining larger O-ring, and install it into the groove of the adap- tor. Install the gasket supplied in the kit. Install the governor, and torque the capscrews 10 lbf·ft (14 N·m). 10. Perform the operational tests in Subject 170 . Business Class M2 Workshop Manual, Supplement 20, September 2011 130/2