Air Dryer, Meritor WABCO System Saver 1200 Plus 42.34 Desiccant Cartridge Replacement WARNING Before working on or around air brake systems and components, see Safety Precautions 100 . Failure to do so may result in personal injury. NOTICE The WABCO System Saver 1200 Plus air dryer can use either a standard or oil coalescing desic- cant cartridge. When replacing the desiccant car- tridge, it is very important to use the same type of cartridge that was originally installed on the dryer. Oil coalescing cartridges can be used in any application, but require more frequent ser- vice intervals (every 1 to 2 years instead of every 2 to 3 years for a standard cartridge).
Do not re- place an oil coalescing cartridge with a standard cartridge, as this may result in contamination and malfunctioning of downstream air system compo- nents. 2 3 1 08/05/94 f421292 1. Seal 2. O-Ring 3. Air Dryer Base Replacement Fig. 1, Desiccant Cartridge Replacement Refer to Fig. 1 for cartridge replacement. 1. Drain the air system. 2. Using a strap wrench, turn the desiccant car- tridge counterclockwise and remove it. 3. Remove and discard the O-ring. 4. Clean the top surface of the dryer base with a commercial cleaning solvent. IMPORTANT: If the air dryer base is damaged, preventing a tight seal, replace the air dryer. 5.
Using a multipurpose, high-temperature grease that resists water, steam, and alkali, lightly coat the surfaces of the new O-ring and the dryer base. Install the O-ring. 6. Thread the desiccant cartridge onto the dryer base (turn clockwise). When the seal contacts the base, tighten the cartridge one complete turn more. Do not overtighten. Business Class M2 Workshop Manual, Supplement 20, September 2011 150/1