Air Dryer, Meritor WABCO System Saver 1200 Plus 42.34 Governor Replacement WARNING Before working on or around air brake systems and components, see Safety Precautions 100 . Failure to do so may result in personal injury. IMPORTANT: When replacing the governor, use only the Meritor WABCO governor specified for use with the System Saver 1200 Plus air dryer. Replacement 1. Remove the mounting bolts, governor and gasket as shown in Fig. 1 . Discard the gasket. 3 2 4 02/24/2011 f422551 1 1. Governor 2. Gasket 3. Air Dryer 4. Mounting Bolt Fig. 1, Replacing the Governor 2. Place the new governor and gasket into position on the air dryer. 3. Using the mounting bolts, install the governor.
Tighten the bolts 15 lbf·ft (20 N·m). Business Class M2 Workshop Manual, Supplement 20, September 2011 190/1