Power Steering System Troubleshooting Procedures 46.09 Troubleshooting Procedures tion three times. The flow rate should return to the flow rate first noted with the load valve open. be limited to prevent excessive pressure from damaging the gear, and the internal PRV pas- sage must be blocked to direct oil flow through the gear. If the flow rate does not return smoothly and quickly, replace the PRV or pump, as required. Use PartsPro ® for the specific VIN to determine if the steering gear is equipped with an internal PRV, which will be listed as a serviceable part under module 536. If the flow rate returns smoothly and quickly, the pump relief valve is ac- ceptable. Go to the next substep.

If a TRW steering gear has an internal PRV but no hydraulic brake booster, see the following heading, Internal Leakage Test Setup, TRW Steering Gears With an Internal PRV , for in- structions on setting up the necessary test com- ponents before proceeding with the following substeps. 6.5 Test the flow of the pump at idle with a load applied. For vehicles with low-pressure steering gears, run the engine at idle and slowly close the load valve until the pressure gauge reads 1000 psi (6900 kPa). Read the flow rate on the gauge, then set the pressure to 1800 psi (12 400 kPa). Read the flow gauge, then open the load valve. Compare the values to those in Table 2 .

ThyssenKrupp rack and pinion steering gears are also equipped with an internal PRV, but cannot be tested for internal leakage. IMPORTANT: Make sure the fluid tempera- ture is approximately 180°F (82°C) and the vehicle is stationary with the front wheels pointing forward. For vehicles with high-pressure steering gears, use 1000 psi (6900 kPa) and 2300 psi (15 860 kPa) as the test load pres- sures. See Table 3 for minimum flow rate. 6.6 Test the maximum flow of the pump with no load applied. 7.1 Run the engine at idle with the load valve open. WARNING Run the engine at 1500 rpm, make sure the load valve is completely open, and read the flow gauge.

If the flow rate is below the mini- mum indicated in Table 2 or Table 3 , replace the PRV or pump, as required. Keep fingers clear of the stop bolt and spacer block during the following test. Make sure that the spacer block contacts the axle stop squarely. Contact that is not square could break the stop bolts or eject the spacer block, which could cause serious personal injury. If the flow rate is above 5.5 gpm (20.8 L/min) on a vehicle with a single steering gear, or 7.7 gpm (28.8 L/min) on a vehicle with an assist cylinder installed, replace the pump. 7.2 Place an unhardened steel spacer, 1-inch (25-mm) thick, between the axle and the stop bolt on one side of the axle.

The spacer should have an extension or handle long enough to keep fingers clear of the axle stop area. A brazing rod or welding rod works well for this purpose. 7. Test the steering gear internal leakage. Select TRW integral steering gears and all Thys- senKrupp rack and pinion steering gears are equipped with an internal PRV that significantly limits maximum supply pressure to protect the steering gear. These gears, unlike gears on ve- hicles fitted with hydraulic brake boosters, cannot be tested for internal leakage by plugging the internal PRV in the gear.

The pump output must NOTICE While running the following test, do not hold the steering wheel in the full-turn position for more than five seconds. Doing so could damage the pump. Business Class M2 Workshop Manual, Supplement 20, September 2011 300/7