Power Steering System Troubleshooting Procedures 46.09 Troubleshooting Procedures NOTICE gauge on the PSSA reaches 2,000 psi (13 790 kPa), then fully open the shutoff valve on the PSSA. Do not leave the PSSA shutoff valve fully closed for longer than five seconds. Doing so could damage the power steering system. 10. Continue with the steering gear internal leakage test (step 9 of the Troubleshooting Steps head- ing above). 8. With the engine on, close the shutoff valve on the PSSA. 9. Set the system relief pressure by closing the ex- ternal relief valve ( Fig.

4 , Item 15) until the Internal Leakage Test Components Part Available From Part Number (Vendor P/N) Item #, Power Steering System Analyzer (PSSA) SPX Kent-Moore J-26487 5 Fig.

4 PSSA Adaptor Kit SPX Kent-Moore J-28593 Relief Valve Plug SPX Kent-Moore J-37130 Connector, Straight Thread with O-Ring Daimler Trucks PDC 23-11470-088 6 Power Steering Hose, 42" Daimler Trucks PDC 14-12694-042 8 Connector, 3/8" Male NPT to 5/8" Beaded Hose Barb Daimler Trucks PDC 23-11321-001 9 Pipe Coupling, 3/8" NPT Parker Hannifin PH 3/8 GG S (3/8 GG-S) 10 Tee, Male JIC with Male NPT Branch * Parker Hannifin PH 8STXS (8 STX-S) 11 Swivel Adaptor, 3/8" Male NPT to Female 37 degree JIC (qty 2) Weatherhead WH 9100X8X6 (9100x8x6) 12 Swivel Nut Run Tee Parker Hannifin PH 8 R6X S (8 R6X-S) 13 3/8" Female NPT Aluminum Relief Valve Threaded Cartridge Body Parker Hannifin B10-2-A6P (PH B102A6P) 14 Aluminum Hydraulic Threaded Cartridge Relief Valve with Knob Parker Hannifin PH RAH101K30 (RAH101K30) 15 * Use steel 37 degree JIC fittings only.

Table 5, Internal Leakage Test Components Business Class M2 Workshop Manual, Supplement 20, September 2011 300/11