Freightliner — Freightliner Business Class M2 Workshop Manual

Fuel/Water Separators, DAVCO 47.01 Removal and Installation Removal the frame rail. If the fuel inlet line was not com- pletely disconnected in the previous step, discon- nect it. WARNING Fluid circulated through the fuel/water separator may be diesel fuel returned from the engine, or engine coolant. Drain the fuel/water separator only when the engine and fluids have cooled. Draining it when the engine is hot could cause severe personal injury due to scalding. If returning fuel is released into the atmosphere, its vapors can ignite in the presence of any igni- tion source. Do not expose the fuel to, or work with, the fuel system near open flame or intense heat.

To do so could cause fire, possibly result- ing in serious personal injury or property dam- age. Installation IMPORTANT: All fittings, including the locking collars, must be very clean as they are installed. A piece of grit or a damaged surface on a seal- ing face or in threads can cause air leaks. Use paste sealer to ensure that the tapered thread fuel line fittings will not leak. Do not use sealer on compression fittings and do not seal the fittings with tape, which will eventually leak. 1. If the inlet fuel line is inaccessible when the fuel/ water separator is mounted on the vehicle, loosely connect the inlet fuel line before mount- ing the fuel/water separator on the frame rail.

Most service procedures are done with the fuel/water separator in place, but some procedures, such as pressure testing, require that the fuel/water separator be removed from the vehicle. To minimize restrictions, keep fuel line routing as smooth as possible, with no low-hanging loops that could trap water. If the fuel line is being made to length on the job, be sure that the inner liner of the hose is not cut by the fitting. Be cer- tain the interior of all fuel lines is clean and free of debris before connecting them, and confirm that all fittings are clean. 1. Shut down the engine, apply the parking brake, and chock the tires. IMPORTANT:

When draining fluid from a fuel/ water separator, drain the fluid into an appropri- ate container, and dispose of it properly. Many states now issue fines for draining fuel/water separators onto the ground. 2. Mount the fuel/water separator on the frame rail and install the mounting fasteners. 2. Put a clean receptacle under the fuel/water sepa- rator and attach a piece of hose to the drain valve, to direct fuel into the receptacle. NOTICE NOTE: Use a hose with a Ѕ-inch pipe thread to fit the drain valve on a Fuel Pro 382. The lower housings on DAVCO fuel/water separa- tors are made of aluminum.

To avoid damaging threads, be careful not to overtighten fasteners or fittings on the fuel/water separator. 3. Remove the vent cap ( Fig. 1 , Item 14) and open the drain valve ( Fig. 1 , Item 1) to drain the fuel to just below the collar level, then close the drain valve. 3. If the fuel inlet line was loosely connected previ- ously, tighten it. If it was not connected, connect and tighten it. 4. Unplug the electric heating element, if equipped, or disconnect the heating fluid lines. 4. Connect the fuel outlet line. Tighten the fitting 25 to 40 lbf·ft (34 to 54 N·m). 5. Disconnect the fuel outlet line. 5.

Install the electric heating element, if equipped, and connect the wiring harness, or connect the fluid heater lines. It does not matter which direc- tion the heating fluid flows through the housing; the lines can be reversed. 6. Disconnect the fuel inlet line. If the inlet line is difficult to reach, loosen the connection, then fully disconnect it after the fuel/water separator is re- moved from the frame rail. 7. Remove the fuel/water separator mounting fas- teners and remove the fuel/water separator from 6. Prime the system 6.1 Ensure that the drain valve is closed. Business Class M2 Workshop Manual, Supplement 20, September 2011 100/1