Freightliner — Freightliner Business Class M2 Workshop Manual

Fuel/Water Separators, Alliance/Racor 47.02 Troubleshooting Troubleshooting Problem—Air Leaking into the Fuel System Problem—Air Leaking into the Fuel System Possible Cause Remedy The drain is not closed. Tighten the drain valve. The sight bowl or filter element is loose. Hand-tighten the sight bowl or filter element until snug. There are loose, broken, or clogged fuel fittings, valves, or filters. Tighten, clean, or repair the fuel fittings, valves, or filters as needed.

Problem—High Water Light Does Not Illuminate For 2 to 5 Seconds When Ignition is Turned to ACCESSORY Problem—High Water Light Does Not Illuminate For 2 to 5 Seconds When Ignition is Turned to ACCESSORY Wiring connections are loose. Tighten connections as needed. Possible Cause Remedy Fuel/water separator is not grounded. Check that power is on, and the fuel/water separator is grounded. Wiring is damaged. Check for damaged wiring and replace as needed. See EZWiring for a diagram of the sensor circuit. Water sensor probe is damaged. Replace the water sensor probe. See Subject 130 for instructions. Business Class M2 Workshop Manual, Supplement 18, September 2010 300/1