Freightliner — Freightliner Business Class M2 Workshop Manual

Liquefied Natural Gas Fuel System 47.03 Safety Precautions Safety Precautions valves only if LNG is needed to operate the engine or to check for leaks. DANGER Repair work on an LNG fuel system should be performed only by qualified technicians trained in automotive LNG system repair. Natural gas vapors are highly flammable. Failure to observe the following safety precautions could lead to ignition of the natural gas, which could cause serious bodily injury or death. Always tighten fasteners and fuel connections to the required torque specification. Overtight- ening or undertightening could cause leaks. Liquefied natural gas (LNG) vapors are highly flam- mable.

Whenever a leak is suspected, immediately shut off all engines and ignition sources. Avoid caus- ing sparks, and stay away from arcing switches and equipment. Extinguish cigarettes, pilot lights, flames, and other sources of ignition in the area and adja- cent areas. Immediately provide extra ventilation to the area. Do not start any equipment until the gas leak is corrected and the area cleared of LNG. Cover eyes and exposed skin with cryogenic- rated protective devices when working on the fuel system or fueling the vehicle. Workshop Precautions Do not store an LNG vehicle indoors for any ex- tended period of time.

Natural gas is nontoxic, but can cause asphyxiation at high enough concentrations simply by excluding adequate oxygen to sustain life. Observe the following safety precautions when LNG vehicles are inside a workshop: Use only safety fluorescent extension shop lights when working around LNG fuel systems. Periodic inspections of the LNG tank are required by law to ensure continued safety. Each fuel tank should be visually inspected at specified intervals for exter- nal damage and deterioration. See the Business Class M2 ® Maintenance Manual for inspection schedule information. Ensure the shop ceiling is equipped with a vent system that will allow gas to escape and dissi- pate.

Ensure the shop is equipped with an alarm system that activates when gas concentration in the air becomes dangerous. If a tank receives an impact, or has deep scratches or gouges, it should be inspected before refilling. The inspection should be performed by a qualified per- son, in accordance with the tank manufacturer’s es- tablished inspection criteria. Have CO 2 fire extinguishers (ABC minimum) located in a highly visible and easily accessible location. Permit no smoking or other ignition sources within thirty feet of an LNG vehicle. Always use a natural gas detector to test the system for leaks, whether an odor is present or not.

A bubble solution can be used to pinpoint the exact location of leaks. Servicing Precautions Avoid open flames or sparks near an LNG ve- hicle. Check the fuel tank pressure gauge periodi- cally to ensure that pressure is within the nor- mal range of 120 to 150 psi (827 to 1034 kPa). In the unlikely event that tank pressure ex- ceeds 230 psi (1586 kPa) and the pressure relief valve does not open automatically, vent the tank outdoors immediately. Observe the following safety precautions when ser- vicing LNG-powered vehicles: Always purge the fuel lines and tank before performing maintenance or repairs on the fuel system.

This can be done by either transferring LNG in the fuel tank to an approved cryogenic- rated container, or by running the vehicle until the tank is empty and the engine stops. Major Repair and Replacement of Parts If a natural-gas-fueled vehicle is involved in an acci- dent, remove the fuel tank from service and have Close the fuel tank shutoff valves before per- forming maintenance and repairs. Open the Business Class M2 Workshop Manual, Supplement 18, September 2010 100/1