Liquefied Natural Gas Fuel System 47.03 Economizer Replacement Replacement 6 7 8 WARNING 9 10 Liquefied natural gas (LNG) vapors are highly flammable. Refer to the safety precautions listed in Subject 100 before servicing the vehicle. Fail- ure to observe these precautions could lead to ignition of the natural gas, which could cause bodily injury, death, or severe property damage. 5 11 12 Additional fuel system component repair, replace- ment, and troubleshooting information can be ob- tained from the fuel system manufacturer’s website: www.nexgenfueling.com . 4 3 1. Shut down the engine and apply the parking brake. 2 2. De-fuel the LNG tank. See Subject 110 for more information. 1 3.
Once all fuel has been removed from the LNG tank, close the fuel shutoff and vapor shutoff valves. 05/05/2010 f470533 1. Economizer 2. Vapor Shutoff Valve 3. Fuel Fill Hose 4. Secondary Relief Valve (red cap) 5. Fuel Fill Fitting 6. Fuel Level Sender Box 7. Primary Relief Valve 8. Tank Pressure Gauge 9. Fill Vent Fitting 10. Excess Flow Valve 11. Fuel Shutoff Valve (liquid) 12. Fill Check Valve 4. Shut down all vehicle electrical systems. 5. Carefully remove the U-tube attached to the economizer and the tank knuckle. See Fig. 1 . 6. Ensuring no threads are damaged, carefully re- move the elbow fitting from the economizer. Fig. 1, Fuel Tank Plumbing Components 7.
Remove and discard the economizer. 8. When installing a new economizer, it is neces- sary to clean the internal economizer threads to prevent metal shavings and debris from collect- ing in the valve seat once installed. 9. Remove the economizer again, then thoroughly clean the threads on the nipple fitting and the economizer with compressed nitrogen or a wire brush. IMPORTANT: Use nickel tape on all non- compression fittings. See the following section, Nickel Tape Application , for more information on using and applying nickel-impregnated or nickel-coated tape. 8.1 Counting each turn, thread the econo- mizer onto the nipple fitting. 8.2 Unscrew the economizer from the nipple fitting.
Using compressed nitrogen or a wire brush, remove all metal shavings and debris from the external nipple threads and the internal economizer threads. 10. Apply nickel tape to the exposed nipple fitting threads, then install the economizer on the nipple fitting. Tighten the economizer one full turn be- yond hand-tight. 8.3 Repeat the above two substeps until no shavings or debris are found in the econo- mizer, always using the same number of full turns for each installation. 11. Using compressed nitrogen or a wire brush, re- move any dirt and debris from the elbow fitting threads, then apply nickel tape to the exposed fitting threads. 12. Install the elbow fitting on the economizer.
Tighten the elbow fitting three turns beyond Business Class M2 Workshop Manual, Supplement 18, September 2010 120/1